High Frequency Desiccators Derm 102
$64.42
$77.3
Description High Frequency Desiccator Derm 102 High Frequency Desiccators Derm Most procedures performed by a High Frequency Desiccator utilize ten watts of power or less. The Derm 102 is economical, 10 watt high frequency desiccator, thoughtfully designed to give practitioners the ability to perform in-office, minor skin procedures such as the removal of skin tags, benign lesions and premalignant lesions. This Bovie unit allows practitioners to provide better patient care in the office, at a sensible price, saving the patient time and money, while increasing their practice revenue. For the practitioner who wants to also use bi-polar electrosurgery along with high frequency desiccation, Bovie offers the Derm 102 High Frequency Desiccator with 10 watts of bipolar power, adjustable in 1/10th watt increments. To utilize this feature the A827V* bipolar cable, a bipolar forcep* and footswitch activation are required.The Derm 102 is packaged ready to use. The unit come with a total of 18 disposable dermal tips. By the time the practitioners utilizes all 18 electrodes, they will have paid for the unit, twice, and generated income for their practice. FEATURES DERM 101 DERM 102 Power 10W 10W Desiccation X X Fulguration X X Bipolar (utilizes A827V* bipolar cable) X 1/10th Watt Power Adjustment X X Universal Power X X Foot Control Setup (utilizes A803* footswitch) 1 step 1 step Foot Control Handpiece Required No No *Sold Separately INTERFACE A) POWER SWITCH Turn the unit power on utilizing the switch on the right side panel of the unit. B) POWER OUTPUT DIAL Set the power output either by using the dial on the front of the unit (B) or on Bovie DERM 102 unit only by the up and down buttons on the handpiece (F). When power level adjustment is being made by the handpiece an audible tone will sound to indicate that the power level has been changed. Depressing and holding the up or down buttons will cause the power settings to change more rapidly for quick adjustment of the output settings. Power output is displayed in “.1” watt increments from 0.1 to 10 watts. NOTICE: The output settings can not be adjusted when the unit is being activated. C) ACTIVE LIGHT When the unit is activated, an audible tone is sounded and the blue active light will illuminate. D) STANDARD ELECTRODE Slide the standard electrode into the handpiece until it is firmly seated. The handpiece will accept most standard 3/32″ electrodes. E) ACTIVATION BUTTON To activate the unit, remove the handpiece from the holder. Place the handpiece in the desired position and depress the activation button. F) POWER OUTPUT BUTTONS Set the power output by pressing the up and down buttons on the handpiece. G) MONOPOLAR OUTPUT RECEPTACLE The monopolar output for the handpiece is on the lower left front of the unit. The handpiece plug is designed to fit in only one direction. Plug the connector from the handpiece into the receptacle on the bottom of the unit. The three button handpiece is designed to give the doctor complete fingertip control of the power output settings. H) GROUNDING PLATE OUTPUT RECEPTACLE To use the optional grounding plate with cord (A802EU), insert the plug of the cord into the grounding plate output and connect the other end into the grounding plate. The plate should be placed underneath the patient at a point where the entire plate is covered by bare skin. The use of conductive gel is recommended. I) BIPOLAR OUTPUT RECEPTACLE (DERM 102 only) To use the optional bipolar cord (A827V), insert the pins into the bipolar outputs. The cord is then plugged into the forceps. A sliding gate behind the monopolar and bipolar outputs prevents the user from using both simultaneously. J) POWER CORD Plug the female end of the power cord into the base of the unit. K) FOOTSWITCH OUTPUT RECEPTACLE The optional footswitch (A803) is plugged into the footswitch output and placed on the floor. The footswitch can be used with monopolar procedures and must be used with bipolar procedures. TECHNICAL SPECS MODE OUTPUT POWER OUTPUT FREQUENCY REPETITION RATE CREST FACTOR @ RATED LOAD VP-P Coagulation 10 W @ 1000Ω 550 kHz ± 44.9 kHz 19.5 kHz ± 10% 10.0 ± 20% 3.3 kV Bipolar 10 W @ 150Ω 550 kHz ± 44.9 kHz 19.5 kHz ± 10% 10.0 ± 20% 1.0 kV Mains Connection: Main Voltage: 100 – 240 VAC ± 10% Main Frequency: 50 – 60 Hertz Main Current: 320mA Max. Power Consumption: 28 VA Dimensions: Height 8.2” (208mm) Width 7.2” (184mm) Depth 2.7” (69mm) Weight: < 1.4 kg (< 3 lbs) Safety: Basic Construction: In accordance with EN 60601-1 Mode of Operation: Intermittent Operation Output Type: TYPE BF Duty Cycle: 10sec on / 30sec off Main Fuses: T 400mAL, 250V Warranty: 4 years (Unit) Click here for more Electrosurgical Equipment
Electrosurgery (39)